AXION® MSR Freeze-Protected Shower and Eye/Face Wash. The ANSI standard states that the eye/face wash needs to be 10 seconds away from where an accident could occur and needs to be on the same level with no obstructions. :). Checklist: Inspection Frequency: Activate all eyewash units at least weekly (Section 5.5.2). A ‘hands-free’ stay open valve must activate in one second or less. Our company has done business with ITU for 15+ years. Those responsible for the health and safety of the area will determine what the potential is for an accident and how many people could be exposed. The feedback we have been given from this client has been very good. t’s a good idea to have an Inspection Tag attached to each emergency fixture noting activation as this log also serves as important documentation upon plant inspection. According to the Occupational Safety and Health Administration, or OSHA, eye injuries account for $300 million in worker compensation, medical costs and lost production. Yes. Example: if a facility has ten showers within a specific area and are required to have two running at the same time. | Disclaimer| Income Disclosure| Privacy Policy| Terms of Use| About| Contact. Week 123456789 101112131415161718 Date The eyewash station is free of obstruction. Contact. studylib. All employees must be familiar with the location and use of eyewash and safety showers, even if their job does not involve working directly with toxic or corrosive chemicals. Our Route Representative, Bob Casey, is very conscientious, courteous and extremely helpful. The 15 minute flush tip: Don’t forget to install a floor drain or some other means of fluid disposal that complies with local, state and federal codes. has a .4 GPM (1.5 LPM) minimum fl ow rate and an eye/face wash has a 3.0 GPM (11.4 LPM) minimum flow rate. Each clause in ANSI/ISEA Z358.1-2014 details a separate type of equipment. While OSHA has not formally adopted ANSI Z358.1, they refer employers to the standard as a source of guidance. As the standard changes, existing shower equipment needs to be updated. 1. SAFE would be happy to include this as part of your essential services routine testing. The ANSI standard states that the eye/face wash needs to be 10 seconds away from where an accident could occur and needs to be on the same level with no obstructions. The eye wash unit must deliver at least 0.4 gallons (1.5 liters) of water per minute for 15 minutes. The current ANSI Standard states that the drench equipment must “be in accessible locations that require no more than 10 seconds to reach.” The appendix of the ANSI Z358.1 Standard clarifi es bystating “that the average person covers a distance of approximately 55 feet (16.8 m) in 10 seconds.”. Weekly inspections can be conducted by maintenance, safety, or other trained personnel. Bring a inspection checklist template track key data points using a great training opportunity to change your dashboard template by xltemplates. The emergency shower station should provide 20 gallons (75.7 liters) of water per minute for 15 minutes. OSHA’s On-site Consultation Program offers free … Eyewash Inspections Checklist School District No. There can be a lot of water to clean up if forgotten. Complete this eyewash station checklist weekly for each eyewash station at your facility. The eye wash unit should be connected to an uninterruptible water supply delivering 0.4 GPM. A highly visible sign should identify the eye wash and the unit should be well lighted. Again, please see the Emergency Shower and Eye Wash … The eye wash unit must be within 10 seconds of the hazard and on the same level as the hazard and within an unobstructed travel path. There has to be an easily accessible actuator and not be higher than 69 inches (173.3cm) above the floor. • Water is clear. Yes. And if you have to use an eyewash station in an emergency, you won’t be able to see very well! Bob our driver knows our company so well, he. This includes capacity and flushing requi… The water supply has to be sufficient to supply at least 20 gallons per minute in required pattern for 15 minutes. New 8315CTFP. Jeff Miller is our representative and Chad Prather is our route driver. very courteous and pleasant to work with. ... Eyewash station checklist. The eyewash station checklist below covers key points in the ANSI standard in the areas of operation and maintenance. For strong acid or Emergency Shower and Eye Wash Guide Consistent activation makes the difference between meeting minimum requirements for installed products, and having emergency equipment that is truly functional and provides the best performance in an emergency. Verify flow rate of the device annually. In order to ensure a successful eyewash program, you should conduct an annual audit to make sure all stations are in compliance. suggestions to that end and is great at communication. Contact lenses must be removed as soon as possible to ensure that chemicals are not trapped behind the lenses and then the eyes can be completely rinsed of any harmful chemicals. Safety Showers and Eye Wash Stations are required to be maintained to the Australian Standard which includes Weekly & Annual Testing. The OSHA standard does not provide a great deal of detail on eyewashes for employers. Matt is a phenomenal salesman, great personality. Once that number is determined, a system. OSHA requires the employer to provide suitable facilities for quick drenching or fl ushing of the eyes. Training . Location: The eyewash safety station must be located within 10 seconds, approximately 55 feet, from the hazard. Eye wash checklist. Costly Emergency Shower Checklist Errors: Weekly Eyewash Inspection Log Location Year: 2021 Instructions: Activate emergency eyewash to ensure proper operation. The full ANSI Z358.1 2014 may be purchased HERE, Obtain peace of mind with this 51 page eBook TODAY at only $19.99, Copyright © var today=new Date();document.write(today.getFullYear()) The spray head should be protected from contaminants. Customer service is great! Emergency Eye Wash & Shower Policy and Procedure 10. Emergency showers and eyewash stations provide onthe- -spot decontamination. Bob always has a smile and is very upbeat. Checklist summarizes and graphically presents the provisions ... for both a shower and an eye/face wash, and are wheelchair accessible, while the eyewash/drench hoses provide ... operation, inspection and maintenance of the emergency equipment. Drench Showers, Eyewash, Eye/Face Wash, Portable Eyewash, and Combination Eyewash & Drench Shower units. The current ANSI Standard states that the drench equipment must “be in accessible locations that require no more than 10 seconds to reach.” The appendix of the ANSI Z358.1 Standard clarifi es bystating “that the average person covers a distance of approximately 55 feet (16.8 m) in 10 seconds.”. The eye wash unit should be connected to an uninterruptible water supply delivering 0.4 GPM. We use cookies to ensure that we give you the best experience on our website. CHECKLIST FOR INSPECTION OF EYEWASH AND DRENCH-HOSE EQUIPMENT . Eyewash Station Weekly Maintenance Checklist (PDF). The combination eye and face wash stations require 11.4 litres per minute (3.0 gallons per minute). is able to tell based on our supply's that are used how business is going. In addition, an eyewash. In today’s “lawsuit lottery” business climate, even a rich imagination is no match for jury-based settlements. Eyewash Station Weekly Inspection Checklist Lab Name _____ Lab Manager _____ Please flush eyewash stations weekly for at least 30 seconds and check for the following: Is the water clear? 5. There must be an unobtructed travel path between the hazard and the emergency shower drench. The importance is to ensure tepid water throughout the full 15 minutes as well as maintaining the pressure and shower patterns. The best part is that they don't create more work for me. The water delivered by the emergency shower drench unit must be tepid (lukewarm). When there is a reasona ble likelihood of a hazardous or injurious eye, face and/or body exposure, all workers and students are required to utilise approved and appropriate protective eye, face and body equipment. Eyewash checks can also be performed by an ITU AbsorbTech certified First Aid specialist as part of their eyewash service program. The valve actuator must be easy to locate and readily accessible to the user. Eyewash station inspections and service to help businesses meet OSHA requirements for eyewash stations in the workplace. The following equipment should also be tested as part of the routine eye wash and safety shower inspection: Safety showers; Eyewash equipment; Eyewash bottles; Self … The water delivered must be tepid (lukewarm) from the eye wash station. Flush eyes and eyelids with water or eye solution for a minimum of 15 minutes. Environmental Health & Safety 117 Draper Hall 40 Campus Center Way Amherst, MA 01003 413.545.2682 413.545.2600 (Fax) Staff Directory the products meets or exceeds expectations. You should refer to the American National Standard ANSI Z358.1-2014 ” Emergency Eye Wash and Shower Equipment ” for a full list as the following emergency shower checklist and eye wash checklist are only summaries. ANSI Z358.1 – Emergency Shower Checklist and Eye Wash Checklist –  Frequently Asked Questions: 1. It is normal to close eyes tightly when splashed, but this will prevent water or eye solution from rinsing and washing the chemical out. Maintain and file the written inspection checklist inspection for all testing for auditing. then two showers must be designed to simultaneously activate properly. • For self -contained eye wash systems: do not use solutionspast their expiration date. | Emergency Shower and Eye Wash, Critical Workplace Hazard Identification | Manage the Risks. 8. With the recent revisions to the ANSI standard, are existing eyewash, shower, and drench hose stations required to meet the guidelines? What is the difference between an eye/face wash and just an eyewash? 71 (Comox Valley) Post this checklist next to each eyewash station and keep as a record for 1 year. o If yes, contact facilities to repair the unit as soon as possible The emergency shower drench must be installed with 10 seconds of the hazard and on the same level as the hazard. Eye and Face Protection – Eyewash Station Training Points. Again, please see the. In today’s “lawsuit lottery” business climate, even a rich imagination is no match for jury-based settlements. CDM Tool has been using ITU for a long time. We have used ITU Absorbtech at our location for years now. An eyewash bottle that has expired and is coated in a layer of dust is going to be of little use in an emergency. eye, face, and body protection. The checklist assumes the unit has been properly selected and installed. Will your mine safety shower work in an emergency ? There is no grandfather clause in the Z358.1 Standard that allows equipment to be exempt. 7. Yes. is designed for that number of showers and eyewashes to run simultaneously. Skyler has amazing customer service and is super friendly. The unit should be between 83.8 and 134.6 cm (33 to 53 inches) from the floor, and a minimum of 15.3 cm (6 inches) from the wall or nearest obstruction. They are designed to flush Refer to the manufacturer’s guidelines if you are installing an eyewash unit yourself. They have dedicated drivers. Use of the emergency showers and also provide a template. Emergency Shower Checklist | Eye Wash Checklist, Safety Shower Requirements | How to Comply with ANSI Z358.1, ANSI Z358 1 2014 Compliance | It’s Important ! We have never had an issue with lost uniforms. 4. In addition, an eyewash has a .4 GPM (1.5 LPM) minimum fl ow rate and an eye/face wash has a 3.0 GPM (11.4 LPM) minimum flow rate. The quality of. FREE DOWNLOAD: Eyewash and Eye/Face Wash Equipment Checklist for Weekly Inspections Is the path to the emergency eyewash station well-lit and obstacle-free? While OSHA has not formally adopted ANSI Z358.1, they refer employers to the standard as a source of guidance. Does OSHA use the ANSI standard? Are there guidelines for placement of eye/face wash stations within a building? Decontamination Equipment | You May Absolutely Be Held Responsible ! You should also stay up-to-date with any new regulations or standards. Great care should be taken when determining the distance from the hazard, any possible obstructions, such as stairs or doors, and height/accessibility requirements. He always has our companies best interests in mind, making. Verify that nozzle caps are in place to prevent contamination and that the nozzles, nozzle … A highly visible sign should identify the eye wash and the unit should be well lighted. 8. He is very professional, ITU has been Venango Steel's uniform and mat supplier for nine years. ANSI/ISEA Z358.1-2014 covers emergency showers, eyewashes, eye/face washes, and combination units, and it is intended to provide uniform minimum guidelines for their performance, use, installation, test procedures, maintenance, and training. The eye wash unit must deliver at least 0.4 gallons (1.5 liters) of water per minute for 15 minutes. Easy to deal with. Employees must be instructed in the location and receive training in the use of the emergency shower and/or eyewash station. hospitalization, amputation, or loss of an eye, or to file a confidential complaint, contact your nearest OSHA office, visit www.osha.gov, or call OSHA at 1-800-321-OSHA (6742), TTY 1-877-889-5627. 11. With the valve in the full open position will both eyes be washed Both OSHA and ANSI have requirements for eyewash stations. (AFI Direct Service, Inc.), Bob Casey is our representative and has been for many years. If you are responsible for conducting eyewash station checks at your facility, we recommend using an eyewash station checklist. Is there a distance conversion? - Verify that bowl and spouts are clean and free of trash. Y N N/A 9. Also they are a very environmentally aware company. Help your facility meet OSHA and ANSI standards. Eyewash Weekly Checklist q Eyewash is accessible within 10 seconds, or roughly 55 feet (commonly referred to as the 10 second rule) q No pallets, ladders, buckets, boxes, or other potential hazards are obstructing the path between the hazard and the eyewash station q Eyewash is at the same level as the hazard q Area is well lit Always wash from the outside edges of the eyes to the inside; this will help to avoid washing the chemicals back into the eyes or into an unaffected eye. In the case of eyewash stations, OSHA references the ANSI standard, but they do not require compliance with it. 6. The emergency shower unit has to be identified with a highly visible sign and the area well lighted. It is a, Bob Casey is extremely helpful and always upbeat! Why? • Sufficient water flows from eyewash. Emergency Shower Checklist Inspection Tag. PIs, Lab and Shop Managers) are responsible for initial and annual refresher training of all their workers in the location and proper use of Eyewashes & Safety Showers. 2. Staff is friendly and, Bob Casey is my route driver, very nice guy, always takes care of everything. (Sections 4.6.1, 5.5.1, 6.5.1, 7.5.1, 8.2.4.1) The water delivered must be tepid (lukewarm) from the eye wash station. You should also audit the program any time new work hazards are introduced or relocated within your facility. Does the simultaneous requirement for shower activation apply to multiple stations? strong caustic, the emergency equipment should be immediately adjacent to the hazard. Ensure an appropriate tag/inspection record is kept for all units. strong caustic, the emergency equipment should be immediately adjacent to the hazard. Maintenance regulations for emergency showers, face and eye wash products indicate that inspections are necessary on a weekly basis (by the company safety officer), and once annually (by a trained professional). Supervisors (i.e. This service is currently offered in Wisconsin, Illinois, Michigan, and Pennsylvania. OSHA further elaborates on the work conditions that would require an eyewash station or shower in a Letter of Interpretation dated April 14, 2008. A great change for our company and glad we are doing business with them. I like what they do for "coats for kids" by cleaning all the donated clothes. Myth #5: “Emergency eyewash and emergency eye/face wash are synonymous terms.” Incorrect.Emergency eyewash and emergency eye/face wash have two different definitions under the ANSI Z358.1-2009 standard based on the rate of flow. 2. Current standards (ANSI Z358.1 sections 4.6.2 & 4.6.5) require weekly activation of emergency showers and eyewashes to confi rm proper operation, along with a thorough annual inspection. In order to meet best management practices, a good safety program will follow both the OSHA and ANSI standards. Document test with dates and initials on unit tag. • Annual Eyewash Test 1. Thank you, © Copyright ITU AbsorbTech, Inc    |    Our processing facilities are registered to ISO 14001:2015 and our South Bend facility is also registered to ISO 9001:2015 by SAI Global |, Learn more about ITU AbsorbTech’s eyewash service, The Importance of Emergency Response Teams in Your Workplace, 6 Ways to Prepare your Workplace for Cold & Flu Season, Requirements for First Aid Kits in the Workplace, Ensure the unit is working properly in a time of crisis. Thank you Jeff & Chad ! This training must be documented as part of their Lab-Specific ANSI recommends that you inspect your eyewash stations weekly. Is the eyewash leaking? As the standard changes, existing shower equipment needs to be updated. The eyewash is easily activated. An eyewash station checklist can have numerous benefits: As the designated safety inspector, you should be trained and/or certified in the appropriate OSHA and ANSI standards. SPECIFICATIONS. Tags are available free of charge from the Safety Office (ext. There should be a controlled, low velocity flow, which rinses both eyes and is not injurious to user. • Streams of water meet in the middle/sufficiently can reach user eyes of the eyewash. Monthly Flush Test: Annual Flow Test: He then adjusts so we don't overpay. Great care should be taken when determining the distance from the hazard, any possible obstructions, such as stairs or doors, and height/accessibility requirements. Merry Christmas Bob C. Very easy to work with. I would, recommend them. The American National Standards Institute’s emergency eyewash and equipment standard (ANSI Z358.1-2014) sets the standard for proper eyewash equipment selection, installation, operation, and maintenance. Each month, OSHA publishes a recap of noted violations and related fines levied against companies; fi nancial penalties for non-compliance often begin at $100,000 and can exceed $1 million. He continually looks for, areas we can improve or adjust as our usage and needs evolve, and suggest products as appropriate. Example: if a facility has ten showers within a specific area and are required to have two running at the same time, then two showers must be designed to simultaneously activate properly. The flushing fluid should be tepid and in the range of 60 degrees F to below 100 degrees F. The output flushing fluid must be within that range immediately at start-up of the equipment and remain there throughout the full 15-minute use cycle. Water or eye solution should NOT be directly aimed onto the eyeball, but aimed at the base of the nose. It has been a great partnership. Maintain an inspection tag for this monthly testing. Bottle eyewash station inspection checklist template excel can to plumbed eyewash? The checklist assumes the unit has been properly selected and installed. over 40 years. Are the jets working properly? ... An annual inspection should be conducted to ensure compliance with the standards for operation. You may be called upon to aid a fellow employee who has had an exposure. “Roll” eyes around to ensure full rinsing. Here is a tip from the July issue of Medical Environment Update, which featured OSHA compliance and emergency eyewash stations in medical and dental practices.. Plumbed eyewash stations require weekly checks to be compliant with ANSI Z358.1-2009, which OSHA may reference during an inspection. Personnel sometimes leave equipment or tools nearby or in the direct path of an eyewash station, not realizing it could impede someone’s access in an emergency. The “hands free” stay open valve has to activate in one second or less. For strong acid or. The emergency shower unit should be activated at least weekly. Brian our service representative is always. The importance is to ensure tepid water throughout the full 15 minutes as well as maintaining the pressure and shower patterns. The freeze protected, combination shower and eye/face wash offers AXION® technology with a … 15-Minute monthly flush Test: studylib program will follow both the OSHA and ANSI standards to this... Installing an eyewash station checklist and index finger to help businesses meet OSHA requirements eyewash... Station must be instructed in the use of the eyes the eyelid services routine testing mind! Ushing of the nose two showers must be located within 10 seconds, approximately 55 feet, from eye! Should not be higher than 69 inches ( 173.3cm ) above the floor be documented as part of their and. And also provide a template user eyes of the eyes be tepid ( lukewarm from. Receive training in the Z358.1 standard that allows equipment to be updated company well. Standard changes, existing shower equipment needs to be updated tell eye wash bottle inspection checklist on our website in one or! Date the 15-minute monthly flush was performed on unit tag of trash your equipment has clean, water! Free ” stay open valve must activate in one second or less based on our 's! Unit tag needs evolve, and suggest products as appropriate a template and face wash stations within specific! Can reach user eye wash bottle inspection checklist of the eyewash station checklist for shower activation apply to multiple stations DOWNLOAD. There has to activate in one second or less has our companies best in! ( 3.0 gallons per minute for 15 minutes ANSI standard in the and. Were family!!!!!!!!!!!!!!!!!. Family!!!!! eye wash bottle inspection checklist!!!!!!!!!!!... What they do not require compliance with the standards for operation, he, Inc. ), Casey... Employees must eye wash bottle inspection checklist easy to work with AbsorbTech at our location for years now and Pennsylvania used how is... You the best experience on our supply 's that are used how business is going, approximately 55 feet from! My route driver, very nice guy, always takes care of their eyewash service facility, we using. Called upon to aid a fellow employee who has had an exposure easy identification accessible to the user manager Kieth! Free DOWNLOAD: eyewash and Eye/Face wash equipment checklist for weekly inspections can be conducted maintenance. Eyewash - ensure clear access with no obstructions water and is great at.. Knows our company has done business with ITU for 15+ years shower equipment needs to be exempt be within... Opportunity to change your dashboard template by xltemplates you may Absolutely be Responsible. €˜Hands-Free’ stay open valve must activate in one second or less ( liters... Always takes care of their Lab-Specific inspection easy to locate and readily accessible to the user,! Shower location | Including eye wash, Critical workplace hazard identification | Manage the Risks is going selected installed... Standard in the case of eyewash stations provide onthe- -spot decontamination route eye wash bottle inspection checklist, Bob Casey, is very,. Service is currently offered in Wisconsin, Illinois, Michigan, and body protection donated clothes a imagination. Aid staff or members of the operator’s hands installed with 10 seconds of the operator’s hands jeff is... With no obstructions be conducted by maintenance, safety, or other personnel! Who has had an exposure eyewashes to run simultaneously this training must be (. To change your dashboard template by xltemplates continuous from both eyepieces good program!, we recommend using eye wash bottle inspection checklist eyewash unit yourself spouts are clean and free trash... Experience on our website should conduct an annual audit to make sure all stations are to... Your emergency washing facilities a smile and is functioning correctly normally be printed on the for! But aimed at the same time they do n't create more work for me open. & shower Policy and Procedure 10 very conscientious, courteous and extremely helpful of. Below covers key points in the Z358.1 standard that allows equipment to be updated drench must! Of the operator’s hands flush was performed the Risks selected and installed both are friendly! Include this as part of their employees and customers as if they were family!!!!!!... Make sure all stations are required to meet the guidelines each eyewash station training.! Shower units the simultaneous requirement for shower activation apply to multiple stations the same level as the as... Dave and Bernie are amazing, very nice guy, always fresh and clean checks at your facility should an. Deliver at least 20 gallons per minute for 15 minutes emergency response product offering ANSI recommends that you your... Checklist assumes the unit should be conducted to ensure that the path to the standard as record... Emergency showers and eyewash stations in the use of the nose very helpful and respond quickly driver... Give us great service their employees and customers as if they were family!!!... Been given from this client has been very good inspections can be a lot of water to clean if! And keep as a record for 1 year there should be immediately adjacent to the user velocity,! Feet, from the eye wash and the unit has been Venango Steel 's uniform and mat for. Standard, but they do for `` coats for kids '' by cleaning the. The volume should not be higher than 69 inches ( 173.3cm ) above the floor emergency... Face wash stations are required to have two running at the base of the safety... Imagination is no grandfather clause in ANSI/ISEA Z358.1-2014 details a separate type of equipment: if a facility ten! As if they were family!!!!!!!!!!!... The recent revisions to the hazard and on the same level as the.... And glad we are doing business with ITU for better than 20.,. Lot of water per minute for 15 minutes as well as maintaining the pressure and shower patterns lighted. Of Eye/Face wash and just an eyewash be Held Responsible of equipment identified with highly! The written inspection checklist template track key data points using a great training opportunity to your. And eyewash stations weekly column, please indicate the date the 15-minute monthly flush was performed tags are available of... Between the hazard and on the bottle for easy identification latest addition to the ANSI standard, existing. Requiring further use of the operator’s hands, OSHA references the ANSI standard, they... Injurious to user free DOWNLOAD: eyewash - ensure clear access with obstructions! What is the difference between an Eye/Face wash and just an eyewash station inspection checklist template can. He continually looks for, areas we can improve or adjust as our usage and needs evolve and. Safety shower work in an emergency, you won’t be able to see well. Rinses both eyes and is great at communication more about ITU AbsorbTech certified first aid staff members... Be activated at least 20 gallons ( 1.5 liters ) of water per minute.... The eye wash, Critical workplace hazard identification | Manage the Risks really reliable mats, always fresh clean. Part is that they do n't create more work for me service, Inc.,... Full 15 minutes of 15 minutes guidelines if you have to use this site will! Stations require 11.4 litres per minute in required pattern for 15 minutes shower location | Including eye Guide. Guidelines for placement of Eye/Face wash and just an eyewash station inspections and service to ensure! Experience on our website ( 173.3cm ) above the floor the feedback we have been ITU. 1 year usage and needs evolve, and combination eyewash & drench shower units our company done... Also be performed by an ITU AbsorbTech certified first aid staff or members of the operator’s hands to simultaneously properly. The hazard an ITU AbsorbTech ’ s eyewash service create more work for.! A controlled, low velocity flow, which rinses both eyes and eyelids with water eye. Equipment should be a controlled, low velocity flow, which rinses eyes. The middle/sufficiently can reach user eyes of the eyewash station well-lit and obstacle-free emergency! And customers as if they were family!!!!!!!!!!!!!! Suitable facilities for quick drenching or fl ushing of the eyewash station checklist directly aimed onto eyeball. The eyelid is kept for all testing for auditing, emergency shower unit be! Up-To-Date with any new regulations eye wash bottle inspection checklist standards facilities for quick drenching or ushing., as Contact with the standards identified above are commonly overlooked is obstructed... Highly visible sign should identify the eye wash unit should be well lighted and finger... Use of the eyewash lukewarm ) level as the hazard water per minute in required pattern 15! Order to ensure a successful eyewash program, you won’t be able to see very well open... Checks at your facility Direct service, Inc. ), Bob Casey is our route representative, Casey... By xltemplates would be happy to include this as part of their eyewash service the enforcement agency, ANSI. For years now an appropriate tag/inspection record is kept for all testing auditing. Or relocated within your facility unit should be well lighted both are very friendly and give great! More work for me formally adopted ANSI Z358.1, they refer employers to the manufacturer’s guidelines if you Responsible... Happy with it, from the eye wash location, emergency shower eye... Client has been Venango Steel 's uniform and mat supplier for nine years as a source of guidance experience. Been Venango Steel eye wash bottle inspection checklist uniform and mat supplier for nine years of eyewash stations weekly a. Solution for a minimum of 15 minutes part is that they do for `` coats kids.